Low Voltage Ride-through
Electrical Engineering · Energy Engineering · Last updated: July 30, 2026 · How this entry was written
Definition: Low voltage ride-through is the capability of an electrical device, typically an inverter or generator, to remain connected and operational during a temporary voltage dip or sag on the power grid. This requirement ensures grid stability and prevents unnecessary disconnection of renewable energy sources during faults.
Example in context
“The solar inverter must comply with the grid code requiring low voltage ride-through capability for voltage sags down to 15% of nominal for 500 milliseconds.”
“Güneş invertörü, nominal değerin %15'ine kadar düşen ve 500 milisaniye süren gerilim düşümlerinde düşük gerilim üstesinden gelme kapasitesi gerektiren şebeke koduna uymalıdır.”
Where engineers use it
This term appears in grid interconnection requirements for wind and solar power plants. Engineers use it to design inverters that remain online during short voltage dips, preventing widespread blackouts and ensuring compliance with national grid codes.
Synonyms: LVRT, fault ride-through (specific to low voltage)
Antonyms: voltage swell ride-through
In Energy Engineering
Low voltage ride through (LVRT) is the capability of a wind turbine to remain connected and continue operating during a short-duration voltage dip on the grid. It is a grid code requirement for stable system operation.
“Modern wind turbines are designed with low voltage ride through capability to prevent disconnection during grid faults.”
Practice: can you use “Low Voltage Ride-through” at work?
You are commissioning a 50 MW solar farm and need to verify that each inverter can ride through a three-phase fault that reduces voltage to 20% for 200 ms. How do you test and document compliance?
Show a model answer
“All grid-connected inverters must be tested for low voltage ride-through performance.”
“Low Voltage Ride-through” in 21 languages
| English | Low Voltage Ride-through |
|---|---|
| Turkish | düşük gerilim üstesinden gelme |
| French | tenue aux creux de tension |
| German | Durchfahren von Spannungseinbrüchen |
| Spanish | permanencia ante huecos de tensión |
| Chinese | 低电压穿越 |
| Arabic | الاستمرارية خلال انخفاض الجهد |
| Portuguese | suportabilidade a afundamentos de tensão |
| Russian | низковольтное прохождение |
| Japanese | 低電圧ライドスルー |
| Italian | attraversamento del buco di tensione |
| Vietnamese | khả năng duy trì qua điện áp thấp |
| Hindi | निम्न वोल्टेज राइड-थ्रू |
| Thai | การทนต่อแรงดันต่ำ |
| Indonesian | kemampuan menahan tegangan rendah |
| Korean | 저전압 라이드 스루 |
| Bengali | নিম্ন ভোল্টেজ রাইড-থ্রু |
| Dutch | low voltage ride-through |
| Swedish | lågspänningsridå |
| Finnish | matalajännitteen läpäisy |
| Ukrainian | низьковольтне проходження |
Frequently asked questions
What does Low Voltage Ride-through mean in engineering?
Low voltage ride-through is the capability of an electrical device, typically an inverter or generator, to remain connected and operational during a temporary voltage dip or sag on the power grid. This requirement ensures grid stability and prevents unnecessary disconnection of renewable energy sources during faults. In Electrical Engineering, the term carries a usage-frequency rating of 10/10 in the Engineering English library.
How do you pronounce Low Voltage Ride-through?
Low Voltage Ride-through is pronounced /loʊ ˈvoʊltɪdʒ raɪd θruː/ (IPA). The Engineering English app plays audio for the term and checks your pronunciation with speech recognition.
How is Low Voltage Ride-through used in a sentence?
Example from an engineering context: “The solar inverter must comply with the grid code requiring low voltage ride-through capability for voltage sags down to 15% of nominal for 500 milliseconds.”